Exercises

Exercise 2 – Decay measurement and heat loss

Multi-step · Medium

After class, everyone leaves the classroom from exercise 1. The windows remain tilted open. A CO₂ sensor records the concentration.

Given

V = 192 m³

c₀ = 2200 ppm

c(20 min) = 900 ppm

cₑ = 420 ppm

Inside 21 °C, outside 1 °C

Heating oil: approx. 10 kWh/l

Tasks

a) Air change rate with tilted windows.

b) Ventilation heat loss rate.

c1) Energy lost during 8 hours with tilted windows.

c2) Equivalent quantity of heating oil (without efficiency correction).

Source: HSLU, 11_Luftaustausch_oL.pdf, slide 16.

Practising with this exercise

0 of 4 steps correct

  1. Step 1 · a
  2. Step 2 · b
  3. Step 3 · c1
  4. Step 4 · c2

Related chapter: 11 Air Exchange